Описание

  • Auxiliary release on the front
  • Escape release on the rear with key button
  • Two LED indicators, red and green
  • Actuating head fitted left
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 110 V AC -15%, +10%
Guard locking type
TZ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching elements
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
2131HSlow-action switching contact 3 NC + 1 NO
3131HSlow-action switching contact 2 NC + 2 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors). Escape releaseThis is used for manual release of guard locking from within the danger area without tools. The disable can only be removed and the switch returned to its operating state using a key included (2 keys included).
Housing material Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 3
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Number of guard lock monitoring NO contacts 2
Connection
1 x M20 x 1.5
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid Black
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 230V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC 110 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
LED indicator Operating voltage corresponds to the solenoid voltage
Other
C number
C1828 with escape release
Reliability values according to EN ISO 13849-1
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Horizontal overtravel (A B C D E) 16 mm
''