Описание

  • Auxiliary release on the front
  • Without door monitoring contact
  • Increased horizontal overtravel
Approach direction Horizontal and vertical Can be adjusted in 90° steps Increased overtravel for horizontal approach direction Solenoid operating voltage
  • AC 230 V +10%, -15%
    Guard locking type
    TP2Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
    Switching element
    4131Slow-action switching contact 2 NC + 2 NO
    Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
    Housing material Reinforced thermoplastic
    Weight
    Net 0,5 kg
    Ambient temperature -20 ... 55 °C
    Degree of protection IP67
    Mechanical life 1 x 106
    Contact material Silver alloy, gold flashed
    Switching principle Slow-action switching contact
    Installation orientation Any
    Number of door position positively driven contacts 2
    Number of NO contacts 2
    Connection
    3 x M20 x 1.5
    Approach speed
    max. 20 m/min
    Actuation frequency 1200 1/h
    Guard locking principle Open-circuit current principle
    Locking force Fmax 1300 N
    Locking force FZh 1000 N
    Retention force 10 N
    Extraction force 20 N
    Actuating force 10 N
    Electrical connection ratings
    Thermal rated current Ith 4 A
    Utilization category according to EN 60947-5-1
    AC-15 4A 230V
    DC-13 4A 24V
    Solenoid operating voltage
    AC 230 V -15% ... +10%
    Short circuit protection according to IEC 60269-1
    (Fuse) 4A gG
    Rated insulation voltage Ui 250 V
    Rated impulse withstand voltage Uimp 2,5 kV
    Switching voltage
    Min. at 10mA 12 V
    Switching current
    Min. at 24V 1 mA
    Power consumption 11 W
    Solenoid duty cycle 100 %
    Connection cross-section 0,34 ... 1,5 mm?
    Reliability values according to EN ISO 13849-1
    Monitoring of guard locking and the safety guard position
    B10D 3 x 106
    In combination with Actuator BETAETIGER-P-GTMechanical values and environment
    Overtravel A B C D E 2 mm
    Overtravel K L M N 1,5 mm
    In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
    Overtravel A B C D E 7 mm
    ''